Products

NEW PAD Portable PIM Analyzer

Product information Software interface

1. Product Features

12 inches highlight touch screen and easy to operate Ideal site testing tools with complete function
Supports PDF, JPG and CSV format test reportSupports data playback,stored and print reports
Supports frequency sweep and time sweep test modeSupport 3、5、7、9rd PIM test
Remote control and test feasible 


2.Specifications
2.1 Products
TypeStandardTx FrequencyRx Frequency
JCIMA-900-P2  GSM  935 – 960 MHz890 – 915 MHz
JCIMA-1800-P2DCS 18001805 – 1880 MHz1710 – 1785 MHz
JCIMA-850-P2CDMA869-894 MHz824-849 MHz
JCIMA-1900-P2DCS 18001850 – 1910MHz1930 – 1990 MHz
JCIMA-2100-P2WCDMA2110-2170 MHz1920-2060 MHz


2.2  General Specifications
Functions

PIM , Isolation, Spectrum and VSWR/Return Loss Measurement, PIM Localization

DisplayDigital Display+PAD
OSANDROID, IOS, Microsoft Mobile(PAD like Android, IOS)
Memory4GB DOM
RF Port 1×N(F)  1×DIN(F)
Extend Port1×USB  1×VGA

Radiator

内置风扇
Dimensions408mm x 235mm x 140mm
Weight11Kg
Power SupplyAC110v/220v±10%,50Hz

Power Consumption

350W

2.3  
PIM Analyzer
PIM Test3rd、5rd、7rd、9rd
Test ModeSweep/Point
Output Power2×20W
Power Accuracy
±0.35 dB
Residual Intermodulation< -168 dBc(-125dBm)
Sweep stepper
100KHz
Positioning accuracy
±0.5ppm
Frequency Accuracy
< ±4ppm
Warm-up time
3 minutes


CDMA
GSM
DCS
PCS
WCDMA
F1/F2
F1(MHz)
869~871.4
930~940
1805~1825
1930~1945
2110~2127

F2(MHz)
889~894
950~960
1838~1880
1960~1990
2153~2170

2.4  Spectrum Analyzer
Frequency RangeWide band:100 kHz to 3 GHz
 Narrow Band:CDMA/GSM/DCS/PCS/WCDMA  (Uplink)
Resolution
4,20,100 kHz
Displayed average noise
Typical –130 dBm 
Measurement Accuracy
≤1dB, Typical 0.5 dB
Dynamic Range
75dB
Maximum Input Power                                    
0 dBm(Avg.),+20dBm(Pulse)
Scan Time
1 ms to 5 s
Attenuator0 to 40 dB in 10 dB step

Peak Mark
MarkEach Peak Mark
   Peak Hold

2.5 Isolation Test
Band
CDMA/GSM/DCS/PCS/WCDMA  (Downlink)          
Output+30~+43dBm                                                 
Isolation-120~0dB
Scan TypeTime
Frequency Resolution
100K
Accuracy Resolution   
0.1dB
Measurement Accuracy                                        
±0.25dB

2.6 VSWR/Return Loss Test
VSWR
1.35~10.00
Return Loss     0.00~18.00dB   
Scan Time2s
Frequency Resolution100K
Accuracy Resolution0.1dB
Measurement Accuracy ±0.25dB

2.7 Environmental
Operation Temp. -10°C to +40°C
Storage Temp.-20°C to +60°C
IP RatingIP21
Relative Humidity      5% to 95%(Non-Condensing)
Shock6G/40G